何晓明 沈雄雅 赵月钧 叶冰洁 章舒祺.改良QuEChERS-高效液相色谱-串联质谱法检测植物油中的10种植物生长调节剂[J].中国油脂,2020,45(3):48~53.[HE Xiaoming SHEN Xiongya ZHAO Yuejun YE Bingjie ZHANG Shuqi.Determination of ten plant growth regulators in vegetable oils by improved QuEChERS-high performance liquid[J].China Oils and Fats,2020,45(3):48~53.]
改良QuEChERS-高效液相色谱-串联质谱法检测植物油中的10种植物生长调节剂
Determination of ten plant growth regulators in vegetable oils by improved QuEChERS-high performance liquid
  
DOI:10.12166/j.zgyz.1003-7969/2020.03.011
中文关键词:  QuEChERS  EMR-Lipid  高效液相色谱-串联质谱法  植物油  植物生长调节剂
英文关键词:QuEChERS  EMR-Lipid  high performance liquid chromatography-tandem mass spectrometry  vegetable oil  plant growth regulator
基金项目:国家重点研发计划资助(2018YFC1602800)
作者单位
何晓明 沈雄雅 赵月钧 叶冰洁 章舒祺 1.绿城农科检测技术有限公司杭州 310052 2.丽水蓝城农科检测技术有限公司浙江 丽水 323000 
Author NameAffiliation
HE Xiaoming SHEN Xiongya ZHAO Yuejun YE Bingjie ZHANG Shuqi 1.Greentown Agricultural Detection Technology Co.,Ltd.Hangzhou 310052, China 2.Lishui Bluetown Agricultural Testing Technology Co., Ltd.Lishui 323000, Zhejiang, China 
摘要点击次数: 1555
全文下载次数: 511
中文摘要:
      采用改良QuEChERS技术作为前处理方法,建立了植物油中10种植物生长调节剂(PGRs)的高效液相色谱-串联质谱快速检测方法。样品用酸化乙腈提取,经增强型基质去除吸附剂(EMR-Lipid)净化,然后用高效液相色谱-串联质谱仪多反应监测模式检测,外标法定量。结果表明:方法线性范围1~100 μg/L,10种PGRs线性关系良好,相关系数(r)为0.991~0.998;检出限为0.014~0.188 μg/kg,定量限为0.048~0.625 μg/kg;10种PGRs的回收率在702%~94.7%之间,RSD为1.2%~10.2%。该方法准确、快速、重复性好,适用于植物油中植物生长调节剂的测定
英文摘要:
      A rapid method for the simultaneous determination of ten plant growth regulators in vegetable oils was developed by using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) based on modified QuEChERS sample pretreatment method.Samples were extracted with acidic acetonitrile,and cleaned up by Enhanced Matrix Removal Lipid (EMR-Lipid).The analytes were detected in the multi-reaction monitoring (MRM) mode and quantified by the external standard method.The calibration curves of ten plant growth regulators were linear well in the corresponding concentration ranges of 1-100 μg/L, with correlation coefficient(r) of 0.991-0.998. The limits of detection and quantification were 0.014-0.188 μg/kg and 0.048-0.625 μg/kg, respectively. The average recoveries of ten plant growth regulators ranged from 70.2% to 94.7% with relative standard deviations (RSDs) of 1.2%-10.2%.The method was quick,accurate,and sensitive, and was suitable for the determination of ten plant growth regulators in vegetable oils.
查看全文   查看/发表评论  下载PDF阅读器
关闭
《中国油脂》杂志社 官方网站
地址:西安市劳动路118号 邮编:710082
电话:029-88617441 88621360 88626849 传真:029-88625310
您是第13673243位访客  京ICP备09084417号