武利梅1,吴丽华1,2,赵晶晶2,吴晓霞1,李建科1.反相高效液相色谱法同时测定植物油中8种维生素E异构体[J].中国油脂,2022,47(10):.[WU Limei1, WU Lihua1,2, ZHAO Jingjing2, WU Xiaoxia1, LI Jianke1.Simultaneous determination of eight vitamin E isomers in vegetable oils by RP-HPLC[J].China Oils and Fats,2022,47(10):.]
反相高效液相色谱法同时测定植物油中8种维生素E异构体
Simultaneous determination of eight vitamin E isomers in vegetable oils by RP-HPLC
  
DOI:
中文关键词:  反相高效液相色谱  均质快速提取  植物油  维生素E
英文关键词:RP-HPLC  homogeneous rapid extraction  vegetable oil  vitamin E
基金项目:
作者单位
武利梅1,吴丽华1,2,赵晶晶2,吴晓霞1,李建科1 1.陕西师范大学 食品工程与营养科学学院西安 710119 2.西安市粮油质量检验中心, 西安 710003 
摘要点击次数: 891
全文下载次数: 623
中文摘要:
      为准确、快速地测定植物油中8种维生素E异构体,建立了均质快速提取法结合反相高效液相色谱法同时测定植物油中8种维生素E异构体的方法,并采用该方法对14种常见植物油进行测定。结果表明:与传统的皂化法和固相萃取法比较,均质快速提取法前处理快速简便,测定准确度和精密度高,重现性好;8种维生素E异构体在15 min内可以实现良好分离;在0.5~10 μg/mL质量浓度范围内8种维生素E异构体线性关系良好(R2>0.999),检出限为0.02~0.05 μg/mL,定量限为0.07~0.17 μg/mL,相对标准偏差在2.48%~5.79%之间,加标回收率在90.00%~110.00%之间;不同食用植物油中生育酚和生育三烯酚的种类和含量存在明显差异。建立的均质快速提取法结合反相高效液相色谱法适用于植物油中8种维生素E异构体的同时测定。
英文摘要:
      In order to accurately and quickly determine eight vitamin E isomers in vegetable oils,a method for simultaneous determination of eight vitamin E isomers in vegetable oils by homogeneous rapid extraction combined with RP-HPLC was established, and the method was used to determine 14 common vegetable oils. The results showed that compared with the conventional saponification method and solid-phase extraction method, the homogeneous rapid extraction method was fast and simple, with high accuracy, precision and good reproducibility. Eight kinds of vitamin E isomers could be well separated within 15 min. The linearities of eight vitamin E isomers were well in the range of 0.5-10 μg/mL(R2>0.999). The detection limits, quantitation limits, relative standard deviations and spiked recoveries were 0.02-0.05 μg/mL, 0.07-0.17 μg/mL, 2.48%-5.79% and 90.00%-110.00%, respectively. There were obvious differences in the types and contents of tocopherols and tocotrienols in different edible vegetable oils. The established homogeneous rapid extraction combined with RP-HPLC is suitable for the simultaneous determination of eight vitamin E isomers in vegetable oils.
查看全文   查看/发表评论  下载PDF阅读器
关闭
《中国油脂》杂志社 官方网站
地址:西安市劳动路118号 邮编:710082
电话:029-88617441 88621360 88626849 传真:029-88625310
您是第12426514位访客  京ICP备09084417号