Utilization of thermal energy in the stripper of negative pressure evaporation system
  
DOI:
KeyWord:stripper  secondary steam  utilization of thermal energy  soybean plant  leaching sector
FundProject:
Author NameAffiliation
ZOU Zhijie Tianjin Soybean Technology Co., Ltd., Jiusan Group, Tianjin 300461, China 
Hits: 1245
Download times: 602
Abstract:
      Taking the 2 500 t/d soybean plant as an example, the utilization of the secondary steam thermal energy in the stripper in leaching sector was studied. By adding 200 m2 heat exchanger, the heat exchange between the secondary steam in the stripper and the miscella oil after first evaporator was designed to increase the temperature of miscella oil from 55 ℃ to 62 ℃. It could save steam 1.98 kg/t, reduce heat load 491 952.71 kJ/h. At the same time, the vacuum of the evaporation system was more stable, which was of great significance to the production stability and economic benefits of the oil plant.
View full text   View/Add Comment  Download reader
Close
Magazine Press of CHINA OILS AND FATS
Address:Laodong Road 118 , Lianhu District, Xi 'an City, Shaanxi Province, China Postcode:710082
Phone:008602988617441;008602988621360 ;008602988626849 Fax:008602988625310
You are the number  1040789  Visitors  京ICP备09084417号